for air conditioning

Component measurements

Resistance measured with the unit switched off, at approx. 20°C, unless stated otherwise.
Compressor
Measure at the compressor terminals or on the supply wire conductors.
ComponentValue
Winding (UV = UW = VW)1–5 Ω
Insulation: winding → casing> 10 MΩ
Transformer
To check that the transformer is working correctly, measure the resistance between the terminals.
ComponentValue
Resistance between terminals (normal state)0.1–1 Ω
4-way valve — coil
AC supply. Cooling mode: 0 V. Heating mode: 230 V.
ComponentValue
4-way valve coilapprox. 2 kΩ ±6%
EEV valve — coil (winding groups)
The coil has 2 winding groups — measure each group individually. If the result deviates significantly from the table, the EEV coil is damaged.
WhiteYellowOrangeBlueBrownRed
White0∞92∞46∞
Yellow∞0∞92∞46
Orange92∞0∞46∞
Blue∞92∞0∞46
Brown46∞46∞0∞
Red∞46∞46∞0

Values in Ω.

Fan motor — 3-pin DC
Measure resistance with the unit switched off. Always A = B = C.
ComponentValue
A: White – Red99 Ω ±7%
B: White – Yellow99 Ω ±7%
C: Yellow – Red99 Ω ±7%
Fan motor — AC
Logic: A = B + C (569 = 251 + 318). Black–Red: run winding. Black–White: start winding. White–Red: common winding. If the blade turns with noticeable resistance, the motor is damaged. Also check the capacitance of the run capacitor on the board.
ComponentValue
A: Red – White569 Ω
B: Red – Black251 Ω
C: Black – White318 Ω
Fan motor — 5-pin DC (diode test, motor disconnected)
Meter's red probe to GND (Black pin), black probe in turn to each of the remaining pins.
ComponentValue
Vm (Red) – GND0.7–0.9 V
VCC (White) – GND0.4–0.6 V
FG (Blue) – GND1.5–2.0 V
Vsp (Yellow) – GND0.8–1.2 V
Fan motor — 5-pin DC (unit running)
Voltage measured under load, with the motor connected.
ComponentValue
Supply: Black (GND) – Red (Vm)≈ 310 V
Control: Black (GND) – White (VCC)≈ 15 V
Speed: Black (GND) – Yellow (Vsp), idle0 V
Low speed≈ 2.72 V
Medium speed≈ 3.35 V
High speed≈ 3.74 V
Stepper motor (louver) — resistance measurement
Measure the resistance between each pair of stepper motor pins.
RedOrangeYellowPinkBlue
Red0187187187187
Orange1870374374374
Yellow1873740374374
Pink1873743740374
Blue1873743743740

Values in Ω.

Condensate pump + condensate level sensor (LCAC — cassette / duct)
Once the condensate level sensor is triggered, the pump is powered. About 25 s after the condensate has been pumped out (the float drops), power to the pump is cut off.
ComponentValue
Condensate pump435 Ω ±8%
Condensate level sensor≤ 0.4 Ω ±8%