R32

Component measurements

Resistance measured at a temperature of 20 °C.
Pump model: number = kW × 10 (044 = 4.4 kW … 160 = 16 kW); HP between brackets.
Reversing valve
ComponentModelResistancePump model
Reversing valve coilSHF-7H-34U-P2085 Ω044 (2.0 HP) / 060 (2.5 HP) / 080 (3.0 HP)
Reversing valve coilSHF(L)-11H-45D12085 Ω100 (3.5 HP) / 120 (4.0 HP) / 140 (5.0 HP) / 160 (6.0 HP)
Electronic expansion valve (EXV)
ComponentModelResistancePump model
Expansion valve coilUVK-18D0346 Ω044 (2.0 HP) / 060 (2.5 HP)
Expansion valve coilUKV-25D52546 Ω080 (3.0 HP)
Expansion valve coil (EVO)PAM-B40YGHQ-1150 Ω100 (3.5 HP) / 120 (4.0 HP) / 140 (5.0 HP) / 160 (6.0 HP)
Expansion valve coil (EVB)DPF(TS1)1.8C-70L46 Ω100 (3.5 HP) / 120 (4.0 HP) / 140 (5.0 HP) / 160 (6.0 HP)
Compressor
ComponentModelResistancePump model
CompressorWHP06840GUKQA8JT6044 (2.0 HP) / 060 (2.5 HP)
CompressorSVB200FCNMC-Lbetween windings 1.21 Ω, to ground >20MΩ080 (3.0 HP)
CompressorSYB2890FDJMC-Lbetween windings 0.63 Ω, to ground >20MΩ100 (3.5 HP) / 120 (4.0 HP)
Compressor (single-phase)MVB40FMLMC-Lbetween windings 0.72 Ω, to ground >20MΩ140 (5.0 HP) / 160 (6.0 HP)
Compressor (three-phase)MVB40FMMMC-Lbetween windings 1.37 Ω, to ground >20MΩ140 (5.0 HP) / 160 (6.0 HP)
DC fan motor (pump model 044/060/080)
ComponentModelResistancePump model
WindingRed–Black2.6 MΩ or greater
WindingWhite–Blackapprox. 28 kΩ
WindingYellow–Blackapprox. 188 kΩ
WindingBlue–Black25 MΩ or greater
DC fan motor (pump model 100/120/140/160)
ComponentModelResistancePump model
WindingRed–Black1 MΩ or greater
WindingWhite–Blackapprox. 40 kΩ
WindingYellow–Blackapprox. 220 kΩ
WindingBlue–Black∞ (open)